beautypg.com

Scaling range, Results, 4 analysis tools – Banner PresencePLUS P4 GEO 1.3 Series User Manual

Page 117: Results7.2.2.5 results, Scaling range7.2.2.6.5 scaling range

background image

An example of narrowing the band of gray scale values is to set the Low at 50 and the High at 200. With these
settings, only gray scale values from 50 to 200 will be used by the Geometric Find tool to determine the threshold
when Adaptive Threshold is specified.

These controls allow the user to “block” dark spots or light spots from influencing the threshold in the image
acquired by the Sensor.

Scaling Range

Scaling Range allows you to set a range from a low of 0.8 to a high of 1.2. In Run mode, this will enable matches
to occur even with slight variations in shape from the reference shape.

Results

The Results field returns the following:

• Total number of shapes above the minimum acceptance level.
• Position of each shape's center. The origin (0,0) is the upper-left corner of the screen.

7.4 Analysis Tools

Analysis tools analyze the information gathered with the Vision tools to create measurements and tolerances
for the Vision tools.

Analysis Tools

BCR/BCR
1.3

GEO/GEO
1.3

EDGE/EDGE
1.3

AREA/AREA1.3

OMNI/OMNI
1.3

OMNI
Color

ProII/ProII
1.3

ProII
Color

Location
Tools

No

No

No

No

Yes

Yes

Yes

Yes

Coordinate
Tool7.4.2
Coordinate
Tool

on

page 134

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Communication
Tool7.4.1

117

Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com

Tel: 763.544.3164

P/N 000000

PresencePLUS Software Tools

7/2009

This manual is related to the following products: