Scaling range, Results, 4 analysis tools – Banner PresencePLUS P4 GEO 1.3 Series User Manual
Page 117: Results7.2.2.5 results, Scaling range7.2.2.6.5 scaling range
![background image](/manuals/587311/117/background.png)
An example of narrowing the band of gray scale values is to set the Low at 50 and the High at 200. With these
settings, only gray scale values from 50 to 200 will be used by the Geometric Find tool to determine the threshold
when Adaptive Threshold is specified.
These controls allow the user to “block” dark spots or light spots from influencing the threshold in the image
acquired by the Sensor.
Scaling Range
Scaling Range allows you to set a range from a low of 0.8 to a high of 1.2. In Run mode, this will enable matches
to occur even with slight variations in shape from the reference shape.
Results
The Results field returns the following:
• Total number of shapes above the minimum acceptance level.
• Position of each shape's center. The origin (0,0) is the upper-left corner of the screen.
7.4 Analysis Tools
Analysis tools analyze the information gathered with the Vision tools to create measurements and tolerances
for the Vision tools.
Analysis Tools
BCR/BCR
1.3
GEO/GEO
1.3
EDGE/EDGE
1.3
AREA/AREA1.3
OMNI/OMNI
1.3
OMNI
Color
ProII/ProII
1.3
ProII
Color
Location
Tools
No
No
No
No
Yes
Yes
Yes
Yes
Coordinate
Tool7.4.2
Coordinate
Tool
on
page 134
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
117
Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com