6 Methods / Parameters

780/781 pH/Ion Meter, Manual

71

6.5

Direct ion measurement (781 only: Conc

mode)

6.5.1

Type of measurement

PARAMETER Conc

meas.type

:

The type of measurement describes the analytical principle of ion

measurement.

meas.type:

direct, std.add, smpl.add

In general a differentiation is made between direct measurement and

the standard or sample addition methods. The selection of the method

parameters depends on the measurement type which has been cho-

sen. All the method parameters for direct ion measurement are de-

scribed in this section. The descriptions of the

ion parameters

,

measuring parameters

and

calculation parameters

which this

section contains also apply to the standard addition and sample additi-

on types of ion measurement. As a result the following explanation of

the parameters for the standard and sample addition in Section 6.6 is

limited to the specific method parameters.
Please note that changing this Conc parameter meas.type does not in-

clude a change of the current method. Within the mode Conc a method

contains all parameter settings.

6.5.2

Ion parameters

PARAMETER Conc

:

ion parameters

: ├

ion type

ion name

ion charge

conc.unit

The ion parameters describe the name, charge and concentration units

of the ion to be determined.

Ion: Ag(+1), BF4(-1), Br(-1), Ca(+2), Cd(+2),

Cl(-1), CN(-1), Cu(+2), F(-1), I(-1), K(+1),

Na(+1), NH4(+1), NO2(-1), NO3(-1), Pb(+2),

S(-2), SCN(-1), SO4(-2), own

The name of the analyte can be selected here. The additional option

'

own

' allows the analyte to be determined to be given its own name

and charge:

ion name

7 ASCII characters

ion charge

-9...-1, 1...9