beautypg.com

Rockwell Automation 2755 Decoded Hand-Held Scanner User Manual

Page 54

background image

Configuring the Scanner

3–15

Publication 2755-6.2

The modifier character is the sum of the applicable option values based
on the following table.

Code Type

Option Value

Option

0

No Check character or Full ASCII processing.

1

Reader has checked one check character.

2

Reader has stripped check character.

Code 39

4

Reader has performed Full ASCII character
conversion.

Example:

A Full ASCII bar code 1234 with check character W,

A+I+MI+DW

, can be transmitted as

]A7

1234 where

7 = (1+2+4).

0

Standard data packet. No Function code 1 in first
symbol position.

1

Function code 1 in first symbol character position.

Code 128

2

Function code 1 in second symbol character position.

Example:

A Code (EAN) 128 bar code 12345 with Function 1
character in the first position,

Fcnt1

12345 will

transmitted as

]C1

12345.

0

Standard packet in full EAN country code format,
which is 13 digits for UPC-A and UPC-E (not including
supplemental data).

1

Two digit supplement data only.

EAN/UPC

2

Five digit supplement data only.

4

EAN-8 data packet.

Example:

A UPC-A bar code 012345678905 will be transmitted
as

]E0

0012345678905.

0

No check digit processing.

1

Reader has checked check digit.

Interleaved

2

Reader has stripped check digit before transmission.

2 of 5

Example:

An I 2 of 5 bar code without check digit, 4123 will be
transmitted as

]I0

4123.