Configuring the scanner, Scanner default settings – Rockwell Automation 2755 Decoded Hand-Held Scanner User Manual
Page 41
Configuring the Scanner
3–2
Publication 2755-6.2
Configuring the Scanner
1. Connect the interface cable to the scanner.
2. Apply power to the interface cable (if required).
3. Scan the SCAN THIS SYMBOL FIRST bar code (found in Bar Code
Programming Guide, see page references below).
4. Then scan the SET SCANNER FOR (SYNAPSE or ADAPTASCAN)
CABLE OPERATION bar code.
5. Select the scanner cable type. Scan ENABLE SYNAPSE CABLE if
you are using one of the Synapse cables (RS-232, keyboard wedge, or
scanner emulation). Scan the ENABLE ADAPTASCAN PASS
THROUGH CABLE bar code if you are using the AdaptaScan Pass
Through cable (Catalog No. 2755-HDC-GA2-08).
Note: The scanner stores the Synapse cable and AdaptaScan pass
through cable configurations separately. To change between
configurations, scan the ENABLE SYNAPSE CABLE or ENABLE
ADAPTASCAN PASS THROUGH CABLE bar code.
6. Configure the scanner by scanning the bar codes for the options you
want to change. The scanner is currently set with default settings as
listed on this and the following page.
Scanner Default Settings
Programming Guide ➀
Page Reference
Item
Default Setting
For AdaptaScan
Cable
For All Other
Cables
Cable Type
AdaptaScan Pass
Through Cable
2-2
1-2
Symbologies
All Enabled
2-4
1-4
Transmit UPC-A Check Digit
Enabled
2-8
1-8
Transmit UPC-E Check Digit
Enabled
2-8
1-8
Convert UPC-E to UPC-A
Disabled
2-8
1-8
EAN Zero Extend
Disabled
2-9
1-9