Publication 1797-6.5.1 - May 2005
Specifications A-11
1797-OE8 CENELEC I/O Entity Parameters
Signal output (+ to -) for ch 0 to ch 7 (terminals: 0-1; 4-5; 8-9; 12-13; 17-18;
21-22; 25-26; 29-30)
Environmental Conditions
Operational Temperature
Storage Temperature
Relative Humidity
Shock
Operating
Non-Operating
Vibration
-20 to +70
o
C (-4 to +158
o
F)
-40 to +85
o
C (-40 to +185
o
F)
5 to 95% noncondensing
Tested to 15g peak acceleration, 11(+1)ms pulse width
Tested to 15g peak acceleration, 11(+1)ms pulse width
Tested 2g @ 10-500Hz per IEC68-2-6
Agency Certification
CENELEC
UL, C-UL
FM
II (1) 2G EEx ia/ib IIB/IIC T4
II (1D) (2D)
Class I Division 1 & 2 Groups A-D T4
Class I Zone 1 & 2 AEx ib/[ia] IIC T4
Class I Division 1 Groups A-D T4
Class I Zone 1 AEx ib/[ia] IIC T4
Certificates
CENELEC
DMT 00 ATEX E 042 X
UL, C-UL
UL Certificate Number 99.19699
FM
FM Certificate Number 3009806
Protection
Group
Allowed
Capacitance
Allowed
Inductance
U
o
= 21V
I
o
= 93mA
P
o
= 145mW
EEx ia
IIB
1.27
µF
10mH
IIC
188nF
3mH
If concentrated
capacitance
and/or
inductance are
available, use the
following values.
EEx ia
IIB
400nF
10mH
IIC
80nF
2mH
Class I Division 1 Hazardous
C
US
FM