The SV-superset mode of the scanner supports these commands:
If you want to: Use this command: With this
command byte
(hex):
The scanner must
be in this
programming
mode:
See page:
set the baud rate, watchdog rate, VMEbus interrupt level, how
the scanner responds to SYSFAIL, command complete
interrupt, and the input image table interrupt
SETUP
13
program
establish a default scan list and provide status of the I/O
system to the VME master processor
AUTOCONFIGURE
10
program
establish your own scan list
SCAN LIST
11
program
establish a fault dependent group structure
FAULT DEPENDENT GROUP
12
program
change the operating mode of the scanner
SET MODE
20
program
test
run
check adapter status and the scan list without affecting
scanner operation
LINK STATUS
21
program
test
run
transfer a block of data from a specified I/O module to
the scanner
BT READ
01
program
test
run
transfer a block of data from the scanner to a specified
I/O module
BT WRITE
02
program
test
run
continuously transfer a block of data from a specified I/O
module to the scanner
CONTINUOUS BT READ
06
program
continuously transfer a block of data from the scanner to a
specified I/O module
CONTINUOUS BT WRITE
07
program
cause the scanner to reset itself
RESET
none
program
test
run
Waking up the scanner
When the scanner is first turned on, it does a self-test and then goes to
sleep. A VME master processor must wake the scanner up by interrupting
it (writing any value to the scanner’s ID area), which moves the scanner
from sleep mode to program mode. Chapter 7 explains how to wake up
the scanner.
Chapter 8 provides additional programming examples.