beautypg.com

8ć17, Reset command – Rockwell Automation 6008-SV2R VMEbus remote I/O Scanner User Manual

Page 151

background image

Chapter

Programming the Scanner

8

8Ć17

RESET command

/*
**
** RESET() –– soft–reset a 6008–SV2
**
**

This routine forces a 6008–SV2 into the RESET state. Note that this affects BOTH

**

scanner channels. Once the 6008–SV2 has been soft RESET, each channel must be

**

awakened by the wakeup() routine and reconfigured.

**
**

parameters:

pointer to channel structure

**

return values:

none

**
*/

void
reset (channel far *chan)
{

unsigned short far *wordptr;

/* map channel & establish pointers */
map_channel(chan);
wordptr = (unsigned short far *) chan–>VmeIdArea;

/* write the VME ID AREA of scanner */
wordptr[0] = 0x0080;
wordptr[1] = 0xA0A0;

/* unmap the channel */
unmap_channel(chan);
return;

}