Rockwell Automation MDF-SB1304F Kinetix 6000M Integrated Drive-Motor System User Manual
Page 86
![background image](/manuals/580143/86/background.png)
86
Rockwell Automation Publication 2094-UM003A-EN-P - May 2012
Chapter 6
Configuring the Kinetix 6000M System
8. Click OK.
The Tune Bandwidth dialog box opens.
Actual bandwidth values (Hz) depend on your application and may
require adjustment once motor and load are connected.
9. Record your bandwidth data for future reference.
10. Click OK.
The Online Command - Apply Tune dialog box opens. When the test
completes, the Command Status changes from Executing to Command
Complete.
11. Click OK.
12. Determine if your test completed successfully.
for each axis.
If
Then
Your test completes successfully, this dialog box opens.
1. Click OK.
2. Remove the Hardware Enable Input signal
applied earlier
(1)
.
.
Your test failed, this dialog box opens.
1. Click OK.
2. Make an adjustment to motor velocity.
3. Refer to the appropriate Logix motion
module user manual for more
information.
4. Return to
and run the test again.
(1) The hardware enable input for IDM units is on the IPIM module.