Rockwell Automation MDF-SB1304F Kinetix 6000M Integrated Drive-Motor System User Manual
Page 49
Rockwell Automation Publication 2094-UM003A-EN-P - May 2012
49
Kinetix 6000M System Connector Data
Chapter 4
Table 14 - Understanding the Digital Inputs
Table 15 - Digital Input Specifications
Figure 18 - Standard Digital Input Circuits
(1) 24V DC source (range) = 21.6V - 26.4V (supplied by IPIM, not to exceed 250 mA total). Maximum current input = 10 mA.
Figure 19 - High Speed Digital Input Circuits
Pin Connector
Signal
Description
Capture
Time
Edge/Level
Sensitive
4
1
HOME
Optically isolated, single-ended active high signal. Current
loading is nominally 10 mA. Home switch (normally open
contact) inputs for each axis require 24V DC (nominal).
30 ms
Level
4
2/3
REG1
REG2
Fast registration inputs are required to inform the motor
interface to capture the positional information with less
than 4
μ
s uncertainty. Optically isolated, single-ended
active high signal. Current loading is nominally 10 mA. A 24V
DC input is applied to this terminal.
500 ns
Edge
2
2/3
OT+
OT-
Overtravel detection is available as an optically isolated,
single-ended active high signal. Current loading is nominally
10 mA per input. The pos/neg limit switch (normally closed
contact) inputs for each axis require 24V DC (nominal).
30 ms
Level
Parameter
Description
Min
Max
On-state voltage
Voltage applied to the input, with
respect to IOCOM, to assure an on-state.
HOME, and OT+/OT-
21.6V
26.4V
REG1 and REG2
21.6V
26.4V
On-state current
Current flow to guarantee an on-state.
3.0 mA
10.0 mA
Off-state voltage
Voltage applied to the input, with respect to IOCOM, to assure an
off-state.
-1.0V
3.0V
3k
Ω
0.1
μ
F
511
Ω
INPUT
IO_COM
I/O SUPPLY
Customer-supplied
Input Device
24V DC
(1)
IDM
2.49k
Ω
1.27k
Ω
INPUT
IO_COM
I/O SUPPLY
0.001
μ
F
IDM
Customer-supplied
Device
24V DC