beautypg.com

Ipim module connector and signal descriptions, Hybrid cable dc bus connector, Hybrid cable communication signals connector – Rockwell Automation MDF-SB1304F Kinetix 6000M Integrated Drive-Motor System User Manual

Page 39

background image

Rockwell Automation Publication 2094-UM003A-EN-P - May 2012

39

Kinetix 6000M System Connector Data

Chapter 4

IPIM Module Connector and
Signal Descriptions

Hybrid Cable DC Bus Connector

This connector supplies the DC bus voltage. Three wires from the
hybrid power and communication cable (catalog number 2090-
CHBIFS8-12AA

xx) are used to extend this voltage to the first

IDM unit.

Hybrid Cable Communication Signals Connector

The hybrid communication connector extends control
power, communication, and safety signals to the first
IDM unit. The 2090-CHBIFS8-12AA

xx cable

interfaces with this connector.

Terminal

Description

Signal

Strip
Length
mm (in.)

Torque
N•m (lb•in)

1

DC bus supply (-)

DC-

DC-

9.7 (0.38)

0.75 (6.6)

2

Chassis ground

3

DC bus supply (+)

DC+

DC+

Terminal

Description

Signal

Strip
Length
mm (in.)

Torque
N•m (lb•in)

1

Shield

SH1

6.4 (0.25)

0.235 (2.0)

2

Control Power +42V DC

42V +

42+

3

Control Power -42V DC

42V COM

42-

4

CAN Bus Shield

IDM CAN SHIELD

SH2

5

IDM CAN Bus Lo

IDM CAN LO

CN-

6

IDM CAN Bus Hi

IDM CAN HI

CN+

7

System OK out to IDMs

IDM SYSOKOUT

OUT

8

System OK return from IDMs

IDM SYSOKRTN

RTN

9

Safety Shield

SAFETY SHIELD

SH3

10

Safety Enable Input 1

SAFETY ENABLE 1+

SE1

11

Safety Enable Common

SAFETY ENABLE-

SE-

12

Safety Enable Input 2

SAFETY ENABLE 2+

SE2

1

DC-

DC+

1

SH1

42+

42-

SH2

CN-

CN+

OUT

RTN

SH3

SE1

SE-

SE2