Ipim module connector and signal descriptions, Hybrid cable dc bus connector, Hybrid cable communication signals connector – Rockwell Automation MDF-SB1304F Kinetix 6000M Integrated Drive-Motor System User Manual
Page 39
Rockwell Automation Publication 2094-UM003A-EN-P - May 2012
39
Kinetix 6000M System Connector Data
Chapter 4
IPIM Module Connector and
Signal Descriptions
Hybrid Cable DC Bus Connector
This connector supplies the DC bus voltage. Three wires from the
hybrid power and communication cable (catalog number 2090-
CHBIFS8-12AA
xx) are used to extend this voltage to the first
IDM unit.
Hybrid Cable Communication Signals Connector
The hybrid communication connector extends control
power, communication, and safety signals to the first
IDM unit. The 2090-CHBIFS8-12AA
xx cable
interfaces with this connector.
Terminal
Description
Signal
Strip
Length
mm (in.)
Torque
N•m (lb•in)
1
DC bus supply (-)
DC-
DC-
9.7 (0.38)
0.75 (6.6)
2
Chassis ground
3
DC bus supply (+)
DC+
DC+
Terminal
Description
Signal
Strip
Length
mm (in.)
Torque
N•m (lb•in)
1
Shield
–
SH1
6.4 (0.25)
0.235 (2.0)
2
Control Power +42V DC
42V +
42+
3
Control Power -42V DC
42V COM
42-
4
CAN Bus Shield
IDM CAN SHIELD
SH2
5
IDM CAN Bus Lo
IDM CAN LO
CN-
6
IDM CAN Bus Hi
IDM CAN HI
CN+
7
System OK out to IDMs
IDM SYSOKOUT
OUT
8
System OK return from IDMs
IDM SYSOKRTN
RTN
9
Safety Shield
SAFETY SHIELD
SH3
10
Safety Enable Input 1
SAFETY ENABLE 1+
SE1
11
Safety Enable Common
SAFETY ENABLE-
SE-
12
Safety Enable Input 2
SAFETY ENABLE 2+
SE2
1
DC-
DC+
1
SH1
42+
42-
SH2
CN-
CN+
OUT
RTN
SH3
SE1
SE-
SE2