Rockwell Automation Publication 2094-UM003A-EN-P - May 2012

63

Connecting the Kinetix 6000M System

Chapter 5

Ethernet Cable Connections

This procedure assumes you have your ControlLogix or CompactLogix
EtherNet/IP module and Bulletin 2094 control modules mounted and are ready
to connect the Ethernet network cables.

The EtherNet/IP network is connected by using the PORT 1 and/or PORT 2
connectors. The IPIM module uses the EtherNet/IP network only for
configuring the Logix program. Refer to

page 42

to locate the Ethernet

connector on your IPIM module.

Refer to the

Figure 29

to locate the connector on your EtherNet/IP controller

module.

Figure 29 - ControlLogix and CompactLogix Ethernet Port Locations

1 (Front)
2 (Rear)

00:00:BC:2E:69:F6

ControlLogix Platform

1756-ENxT EtherNet/IP Module is Shown

ControlLogix Ethernet Ports

The 1756-EN2T modules have only one port,

1756-EN2TR and 1756-EN3TR modules have two.

Bottom Views

Front Views

CompactLogix 5370 L1, L2, and L3 Controllers
1769-L3xERM Controller is Shown

Port 1, Front

Port 2, Rear