Ethernet cable connections – Rockwell Automation MDF-SB1304F Kinetix 6000M Integrated Drive-Motor System User Manual
Page 63
Rockwell Automation Publication 2094-UM003A-EN-P - May 2012
63
Connecting the Kinetix 6000M System
Chapter 5
Ethernet Cable Connections
This procedure assumes you have your ControlLogix or CompactLogix
EtherNet/IP module and Bulletin 2094 control modules mounted and are ready
to connect the Ethernet network cables.
The EtherNet/IP network is connected by using the PORT 1 and/or PORT 2
connectors. The IPIM module uses the EtherNet/IP network only for
configuring the Logix program. Refer to
to locate the Ethernet
connector on your IPIM module.
Refer to the
to locate the connector on your EtherNet/IP controller
module.
Figure 29 - ControlLogix and CompactLogix Ethernet Port Locations
1 (Front)
2 (Rear)
00:00:BC:2E:69:F6
ControlLogix Platform
1756-ENxT EtherNet/IP Module is Shown
ControlLogix Ethernet Ports
The 1756-EN2T modules have only one port,
1756-EN2TR and 1756-EN3TR modules have two.
Bottom Views
Front Views
CompactLogix 5370 L1, L2, and L3 Controllers
1769-L3xERM Controller is Shown
Port 1, Front
Port 2, Rear