Idm unit connector and signal descriptions, Hybrid cable connector – Rockwell Automation MDF-SB1304F Kinetix 6000M Integrated Drive-Motor System User Manual
Page 44
44
Rockwell Automation Publication 2094-UM003A-EN-P - May 2012
Chapter 4
Kinetix 6000M System Connector Data
IDM Unit Connector and
Signal Descriptions
Hybrid Cable Connector
The information below provides connector pinouts for the IDM unit hybrid
connectors.
Input Connector
Output Connector
Pin
Description
Signal Name
Signal Name
A
DC Bus +
DC +
DC +
B
DC Bus -
DC -
DC -
C
Control Power +42V DC
42V +
42V +
D
Control Power -42V DC
42V COM
42V COM
E
Chassis
Ground
1 Reserved
Reserved
Reserved
2
Brake Override 24V Supply
BRAKE +24V
3
Brake Override Supply Common
BRAKE 24V COM
4
Safety Enable Input 1
SAFETY ENABLE 1+
SAFETY ENABLE 1+
5
Safety Enable Common
SAFETY ENABLE-
SAFETY ENABLE-
6
Safety Enable Input 2
SAFETY ENABLE 2+
SAFETY ENABLE 2+
7
IDM CAN Bus Hi
IDM CAN HI
IDM CAN HI
8
IDM CAN Bus Lo
IDM CAN LO
IDM CAN LO
9
System OK from IPIM or prior IDM
IDM SYSOKIN
IDM SYSOKOUT
10
System OK return to IPIM
IDM SYSOKRTN
IDM SYSOKRTN
Hybrid Input
Connector
Hybrid
Output
Connector
1
3
6
5
4
8
7
9
10
D
C B
A
2
E
5
6
3
1
2
A
B C
E
D
4
8
7
9
10