Tools menu, The following information is displayed – Rockwell Automation MDF-SB1304F Kinetix 6000M Integrated Drive-Motor System User Manual
Page 68
![background image](/manuals/580143/68/background.png)
68
Rockwell Automation Publication 2094-UM003A-EN-P - May 2012
Chapter 6
Configuring the Kinetix 6000M System
The following information is displayed.
Tools Menu
The tools menu provides network setup, sercos light intensity adjustment and
fault help.
To edit a menu item or value, use the arrow keys to select the desired item, then
press “enter.” The up arrow lets you increment the value that is highlighted.
Values will rollover when reaching the end of the list.
The tools menu provides viewing/editing of the following.
IPIM Information
IDM Information
Module
Status:
- IP Address
- OK
-Standby (OK, but no CIP connection)
-Faulted
-Init Fault (Requires reboot)
Status:
Displays IDM status values.
Bus Reg Cap
Percent of shunt capacity being
utilized.
Safety:
“Motion-allowed” or “Safe-off.”
Active
Faults:
Active faults (one per line) will be
displayed.
Sercos
Phase:
Current sercos phase of the IDM: 0 -5.
Utilization:
Percent of continuous DC bus current.
Active Faults: Active faults (one per line) will be displayed.
Selection
Description
Network configuration
Mode
Select Static or DHCP configuration.
IP Address
Edits the IP address.
Subnet mask
Edits the subnet mask.
Gateway address
Edits gateway address.
Primary address
Edits primary name server IP address.
Secondary Name Server
Edit the secondary name server IP address.
Sercos light intensity
Selects high or low intensity. Changes to the light intensity will take effect immediately
and be stored in non-volatile memory. The default setting is “High.”
IPIM fault help
Displays help text for the selected IPIM fault.
IDM fault help
Displays help text for the selected IDM fault.
back
enter
V
V
Network configuration
Sercos light intensity
IPIM fault help
IDM fault help
back
enter
V
V
Network configuration
Sercos light intensity
IPIM fault help
IDM fault help
back
enter
V
V
Network mode
Static IP
Subnet mask
Gateway address
cancel
save
»
V
Static IP
1
11.222.333.444
enter
Use the right
arrow to move
and the up arrow
to change value
enter