Appendix C
Creating EPROM Files

C–3

6. In the TERMINAL Window, select Settings

"

Communications

and enter the following parameters:

Baud Rate, Parity, and Data Bits to match DL20
Stop Bit = 1
Flow Control = Xon/Xoff
No Parity Check and No Carrier Detect Selected
Connector = port connected to DL20

Note: If possible, set the PC communications for COM2, allocating COM1
for the mouse.

7. In the TERMINAL Window, select Transfers

"

Receive Text File

and enter the file name that will contain the hex file for burning the
EPROM, i.e. U EPROM.H.

Note: Don’t exit TERMINAL.exe.

8. At the DL20 keyboard, send the file by pressing [ENTER]. The timer

will start a countdown beginning at 15. At the end of the countdown, the
file is transferred.

9. When the DL20 has finished sending the file, select Stop on the bottom

bar of the terminal window.

10. The file is now in a Motorola hex format that can be used to program

an xx ’128 EPROM.