Chapter 8
Special Functions

8–14

Setting Serial Port

After setting parity, you are prompted for the RS-422 port.

USE 422 IN? N

The DL20 RS-422 port can transmit and receive data from other DL20
devices used as addressable masters or slave DL10 / DL50 displays.

If you want to use the port as an output, answer No. All data output at the
RS-232 port will also be transmitted at the RS-422 port. Set the port to
output if slave displays or addressable masters are being used.

If you want to use the port as an input, answer Yes. Data can then be
received at the RS-422 port just like the RS-232 port.

After selecting RS-422 port direction, you are prompted for a blank line
between messages.

PRINT BLANK LINE?

Answering No reduces the amount of paper used and answering Yes makes
the printout easier to read.

Serial Port Default Values
Table 8.A lists the default values for the serial port.

Table 8.A
Serial Port Defaults

Parameter

Setting

Options

Printer Carriage Width

80 Columns

20 - 220 Columns

Number of Nulls

4

0 - 250

Baud Rate

9600

300, 1200, 9600

Parity

None

None, Odd, Even

422 Port Direction

Output

Input or Output

Print Blank Line

Yes

Yes or No

Setting Up I/O
Port Functions