Appendix B
Tape Recorder Setup

B–10

The EPI STR-LINK Recorders can be used as as storage device for DL20
messages. There are DIP switches inside the STR-LINK II and III which
configure its operation. Refer to the user manual for the data recorder to
access DIP switches. The DIP switches must be set as follows:

STR-LINK II Switch Settings

I/O Board DIP Switch

Switch 1 Open
Switch 2 Open
Switch 3 Open
Switch 4 Closed

Tape Interface Board DIP Switch

Switch 1 Open
Switch 2 Closed
Switch 3 Open
Switch 4 Open
Switch 5 Open
Switch 6 Closed
Switch 7 Closed

The front panel switches must be set as follows:

Baud Rate

1200

I/O Select

RS-232

Stop Bits

1

Mode Select

Full Duplex

STR-LINK III Switch Settings

10 Position DIP Switch

Switch 1 Left
Switch 2 Left
Switch 3 Left
Switch 4 Right
Switch 5 Left
Switch 6 Right
Switch 7 Right
Switch 8 Right
Switch 9 Left
Switch 10 Right

The front panel switches must be set as follows:

Track Select

Both

Baud Rate

1200

EPI STR-LINK
Data Recorders