Rockwell Automation 1756-HIST2G FactoryTalk Historian ME 2.2 User Manual
Page 311

G • T
ROUBLESHOOTING
301
1. From Control Panel > Administrative Tools, run the IIS Admin Manager.
Expand the virtual directory FactoryTalk/Security/Web Service, then right click
on FactoryTalk\Security\WebService\200810.asmx to select Browse. You can
now test the FactoryTalk Security (FTSecurity) service interfaces.
2. From Control Panel > Administrative Tools, run Services.
Change the startup type for ASP.NET State Service to automatic. Ensure that the
asp.net service is started. This deploys the web service to the following URL:
http://<host name>:<port_number>/ FactoryTalk/Security/WebService/
200810.asmx.
3. Configure FactoryTalk Directory.
a) Create an administrative user on the local machine that hosts the FactoryTalk
Historian servers.
b) Open the FactoryTalk Administration Console, and create a corresponding user
with the same name and password. Add it to Administrator group.
4. From the Windows menu, go to FactoryTalk Tools > FactoryTalk Directory
Configuration Wizard and select Network Directory.
Enter the administrator user and password, and re-enter it. Wait for a moment and
check the summary. If all is successful, close the Network Directory.