Then go to the module web interface and test the module connection to the
FactoryTalk Historian SE or PI server. Depending on what type of data transfer server
you are configuring, perform the steps in one of the following sections.
A
PPLICATION
T
RUSTS
(F
ACTORY
T
ALK
H
ISTORIAN
SE)
To successfully transfer data between FactoryTalk Historian ME and FactoryTalk
Historian SE, you must create two application trusts on the FactoryTalk Historian SE
server: webs and datatransfer. To do so, perform the following steps:
1. Launch the FactoryTalk Historian SE SMT application. From the Windows Start
menu run Programs > Rockwell Software > FactoryTalk Historian SE > System
Management Tools.
2. After SMT launches, go to the left-side System Management pane and click [+]
next to the [Security] item.
3. From the list of Security plug-ins, click the Trusts option.
4. From the Trust menu bar in the main window, select the drop-down menu on the
[New] option. The Wizard option is checked by default.
5. The Add Trust Wizard window is launched. The Trust Wizard will ask for various
pieces of information to create a trust on the FactoryTalk Historian SE that is
currently connected.