This chapter provides a list of replacement parts and a list of
replacement terminal blocks for your SLC 500 controller.
Replacement Cables and
Connectors
Description
Cat. No.
Chassis Interconnect Cable - The 1746-C7 cable is a 152.4 mm (6 in.) ribbon cable used when linking modular hardware
style chassis up to 152.4 mm (6 in.) apart in an enclosure.
1746-C7
Chassis Interconnect Cable - The 1746-C9 cable is a 914.4 mm (36 in.) cable used when linking modular hardware style
chassis from 152.4 mm (6 in.) up to 914.4 mm (36 in.) apart in an enclosure.
1746-C9
Chassis Interconnect Cable - The 1746-C16 cable is a 1.27m (50 in.) cable used when linking modular hardware style
chassis from 0.914m (36 in.) up to 1.27m (50 in.) apart in an enclosure. This is the longest chassis interconnect cable
recommended by Allen-Bradley.
1746-C16
32 Point Mating Connector - This connector is used for terminating a user-made cable. It is compatible with the DIN
RAIL mountable terminal block interface module, catalog number 1492-IFM40x (used with 32-point I/O modules).
1746-N3
Replacement Processor to Peripheral Programming/Communication Cable - This 1.8 m (6 ft) cable is used to connect
the interface converter to the SLC 500 controller when using personal computer interface software. This cable is also
used to connect the Hand-held Terminal to the SLC 500 controller and to connect the Data Table Access Module to the
SLC 500 controller.
1747-C10
Replacement Processor to Isolated Link Coupler Cable - This 304.8 mm (12 in.) cable is used to connect the SLC 500
controller to the isolated link coupler.
1747-C11
Communication Module to Isolated Link Coupler Cable - This 914.4 mm (36 in.) cable is used to connect communication
modules (for example, 1746-BAS, 1747-KE, and 1747-UIC interface) to the isolated link coupler. The isolated link
coupler must be powered by an external power supply or connected to a device with a 1747-C10 or 1747-C11 cable.
1747-C13
Replacement Processor to Peripheral Programming/Communication Cable - This 6.09 m (20 ft) cable is used to connect
the interface converter to the SLC 500 controller when using personal computer interface software. This cable is used
to connect the Data Table Access Module to the SLC 500 controller.
1747-C20
SLC 5/03, SLC 5/04, and SLC 5/05 RS-232 Programmer Cable - This 3.96 m (12 ft) cable has two 9-pin DTE connectors
and is used to connect the SLC processor RS-232 channel (channel 0) to a personal computer serial port.
1747-CP3
SLC 5/03, SLC 5/04, and SLC 5/05 Communication Cable - This 45 cm (17.7 in.) cable has two 9-pin DTE connectors and
is used to connect the SLC processor RS-232 channel (channel 0) to port 1 of the 1761-NET-AIC advanced interface
converter.
1761-CBL-AC00
SLC 5/03, SLC 5/04, and SLC 5/05 Communication Cable - This 2 m (6.5 in.) cable has a 9-pin DTE and an 8-pin mini
DIN connector and is used to connect the SLC processor RS-232 channel (channel 0) to port 2 of the 1761-NET-AIC
advanced interface converter.
1761-CBL-PM02
SLC 5/03, SLC 5/04, and SLC 5/05 Communication Cable - This 45 cm (17.7 in.) cable has a 9-pin DTE and an 8-pin mini
DIN connector and is used to connect the SLC processor RS-232 channel (channel 0) to port 2 of the 1761-NET-AIC
advanced interface converter.
1761-CBL-AP00