Model 498.65a-10 eight-channel card settings, Model 498.65a-11 d/a card settings – MTS Series 793 Utility Software User Manual
Page 85

Model 498.65A-10 Eight-Channel Card
Settings
Description
Item
The Model 498.65A-10 8-A/D mezzanine card, available for
installation on ADDA boards, provides 8 channels of A/D with digital
498.65A-10 8-A/D
mezzanine card icon
filtering. Filter settings can be applied to controller feedback, scope,
meter, and limit detector signals. Each D/A mezzanine card definition
is followed by eight signal definitions.
Address: Describes the proximity of the mezzanine card within the
circuit board. This value is generated during initialization, and should
Properties tab
be changed only if the value read in from an existing .hwi file is in
error.
Filter: Off/On.
Analog Input n
Channels tab
Specifies an externally conditioned signal in the range of +/-10V.
High Level
Excludes inputs to the selected channel.
No Channel
Chassis: Not applicable.
497.13 AC/497.14
AC/497.22 Dual DC
Conditioner icon
Slot: Specifies which slot the circuit board occupies in the chassis.
Channel: Not applicable.
Filter: Off/On.
Connector: Not applicable.
Model 498.65A-11 D/A Card Settings
Description
Item
The analog output definition describes the D/A Analog Output
mezzanine card.
498.65A-11 8-D/A
mezzanine card icon
The connector specification identifies the rear panel connector that
is available for analog outputs.
MTS Series 793 Utility Software 71
HWI Hardware Settings