High speed data acquisition settings, Model 494.16 vd/duc hwi settings – MTS Series 793 Utility Software User Manual
Page 69

High Speed Data Acquisition Settings
Each Series 494 DUC has a High Speed Data hwi setting that is used to enable high-speed data
acquisition.
Note:
High-speed data acquisition is required for some applications (for example, the MPT High
Speed Timed Acquisition process).
High-speed data limitations
The Model 494.40 I/O Carrier board allows up to six high-speed data inputs per carrier board. This
could be an issue if four Model 494.26 Dual DUCs are installed on a 494.40 I/O carrier.
Description
Setting
Enables high-speed data acquisition. The high-speed rate is
determined by the system rate and a number of other factors.
True
See your test application documentation for details.
High-speed data acquisition is not available.
False (default)
Model 494.16 VD/DUC HWI Settings
Description
Item
Describes the valve driver/DUC mezzanine card.
494.16 VD/DUC mezzanine
card icon
Application Attribute: Not applicable
Type: defines how the card is used and what resources are available.
•
DUC and 2SVD: when configured as a two-stage valve driver,
the DUC portion of this card is available as a system resource.
•
3SVD: when configured as a three-stage valve driver, the DUC
portion of this card is reserved for the valve LVDT.
MTS Series 793 Utility Software 55
HWI Hardware Settings