Model 493.59x encoder card settings, Model 494.40 i/o carrier mezzanine cards – MTS Series 793 Utility Software User Manual
Page 68

Model 493.59x Encoder Card Settings
Encoder mezzanine cards use the following designators for each type of encoder: 1 for absolute
encoders, 3 for incremental encoders, and 5 for Temposonics III encoders
Description
Item
Encoders require a special mezzanine card be plugged into the
ADDA II board. The encoder mezzanine card can occupy any of the
four ADDA II address locations.
493.59-1 U2 Absolute/
493.59-3 U2 Incremental/
493.59-5 U2 Temposonics
III mezzanine card icons
•
The encoder mezzanine card supports four encoder signals.
•
The encoder mezzanine card processes the pulse stream from
an encoder.
Temposonics III sensors require a special mezzanine card on the
ADDA board. The Temposonics III mezzanine card can occupy any
of the four ADDA address locations.
•
The Temposonics III mezzanine card supports two “double-wide”
Temposonics sensor signals.
•
The Temposonics III mezzanine card processes pulses from the
digital output of a Temposonics III sensor.
Filter: On/Off.
Baud Rate: (493.59-1 U2 Absolute and 493.59-5 U2 Temposonics
III only) Select a baud rate. Allows you to change the baud rate if the
cable length requires a slower baud rate
Name: Describes this resource as it will appear in Station Builder
resource lists when opened against an .hwi file.
Analog Input icon
Changing this name may invalidate existing station configurations.
Connector: Describes the connector that joins the resource to the
chassis. This will likely move up to the daughter level.
Model 494.40 I/O Carrier Mezzanine Cards
The mezzanine cards listed in this section can be used in the Model 494.40 I/O Carrier board. The
Model 494.40 board is compatible with FlexTest 40/60/100/200 controllers.
54 MTS Series 793 Utility Software
HWI Hardware Settings