Model 49x.43 multibox i/o board settings, Model 49x.40 i/o carrier board hwi settings – MTS Series 793 Utility Software User Manual
Page 45

Description
Item
Medium System Rate: Must be an integer multiple of the Low System
Rate.
The Low System Rate is always set at 25.6. The Medium System
Rate is typically 256.
Name: Describes this resource as it will appear in Station Builder
resource lists when opened against an .hwi file.
Digital Input/Output icons
Changing this name may invalidate existing station configurations.
Channel: Not applicable.
Model 49x.43 Multibox I/O Board Settings
This board is used with Aero ST controllers.
Description
Item
Slot: Specifies which slot the circuit board occupies in the chassis.
49x.43 Multi-box I/O circuit
board icon
System Rate: 512, 1024, 2048, 4096 and 6144 Hz (binary).
Note:
The System Rate must be an integer multiple of the Medium
System Rate.
Medium System Rate: Must be an integer multiple of the Low System
Rate.
Note:
The Low System Rate is always set at 25.6. The Medium
System Rate is typically 256.
Model 49x.40 I/O Carrier Board HWI Settings
These settings are for the Model 493.40 and 494.40 I/O Carrier boards.
MTS Series 793 Utility Software 31
HWI Hardware Settings