Setting the actual position value (pos-abs-set), Function library, Positioning control – Lenze EVS9332xP User Manual
Page 94: P o s, 9 travel profile generator and setpoints, 9 setting the actual position value (pos−abs−set)

Function library
Positioning control
3.4.9
Travel profile generator and setpoints
3−66
l
EDSVS9332P−EXT DE 2.0
3.4.9.9
Setting the actual position value (POS−ABS−SET)
P O S
P O S - A B S - I N
C 1 3 6 4 / 2
C 1 3 6 5 / 2
P O S - A B S - S E T
C 1 3 6 1 / 2 1
C 1 3 6 0 / 2 1
M C T R L - P H I - A C T
+
P O S - A C T P O S
P O S - T P
C 1 3 6 2 / 7
C 1 3 6 3 / 7
P O S - N O U T - G A I N
C 1 3 6 2 / 5
C 1 3 6 3 / 5
-
C 1 2 2 1 / 3
C 1 2 2 0 / 3
P O S - P H I - A D D
C 1 3 6 6 / 1
C 1 3 6 7 / 1
P O S - A B S - V A L
+
+
+
+
+
-
( T o u c h P r o b e )
0
1
C 1 2 2 1 / 7
h o m e p o s i t i o n
h o m e o f f s e t
C 1 2 2 1 / 1 6
C 1 2 2 0 / 1 6
C 1 2 2 5
S e t
( f e e d b a c k s e l e c t e d u n d e r C 4 9 0 )
C 1 2 2 1 / 8
C 1 2 2 7
( G e n e r a t i o n o f a c t u a l p o s i t i o n )
( I n f l u e n c e o f f e e d f o r w a r d v a l u e s )
9300POS035
POS−ABS−IN
C1365/2
C1364/2 Input for external actual position value, e. g. when using an absolute value encoder with a CAN
interface.
(see Absolute encoders via system bus"
^ 3−40)
POS−ABS−SET
Changeover (position encoder C490) / (ABS−IN)
POS−ABS−VAL
C1220/16
C1221/16
Display as actual position POS−ACTPOS, but without considering setpoint position polarity (C1206),
actual position (C1206), actual home position (display C1220/8) and actual reference dimension offset
(display C1220/7).
POS−ACTPOS
C1220/3
C1221/3
−
Actual position; position relating to real zero
For rating see formula 1
POS−PHI−ADD
C1367/1
C1366/1 Phase difference signal is added to POS−ABS−IN.
Function: With POS−ABS−SET= HIGH the actual position is set to the value POS−ABS−IN. Encoder
increments that have arrived in the setting cycle are not considered in the default. If required, the
encoder change can be connected in the setting cycle; the signal MCTRL−PHI−ACT must be linked with
the input POS−PHI−ADD.
Home position
HIGH = Phase value at POS−ABS−IN is read in for actual position value generation (POS−ACTPOS).
The following values are considered when POS−ACTPOS is generated:
– Position setpoint polarity (C1206)
– Actual position value polarity (C1208)
– Actual home position (display C1220/8)
– Actual reference dimension offset (display C1220/7).