23 phase conversion (convphph2), Phase conversion (convphph2), Function library – Lenze EVS9332xP User Manual
Page 183: Function blocks, Caution

Function library
Function blocks
3.5.23
Phase conversion (CONVPHPH2)
3−155
l
EDSVS9332P−EXT DE 2.0
3.5.23
Phase conversion (CONVPHPH2)
Purpose
Conversion of a phase signal with dynamic fracture.
C O N V P H P H 2
C O N P H P H 2 - O U T
C O N V P H P H 2 - I N
C 1 1 3 7
C 1 1 3 2
C O N V P H P H 2 - N U M
C 1 1 3 5 / 1
C 1 1 3 0 / 1
C O N V P H P H 2 - D E N
C 1 1 3 5 / 2
C 1 1 3 0 / 2
x
y
C 1 1 3 1
C 1 1 3 6
C O N V P H P H 2 - A C T
1
0
0
Fig. 3−108
Phase conversion (CONVPHPH2)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
CONVPHPH2−IN
ph
C1137
dec [inc]
C1132
3
−
CONVPHPH2−NUM
a
C1135/1
dec
C1130/1
1
Numerator
CONVPHPH2−DEN
a
C1135/2
dec
C1130/2
1
Denominator (with absolute−value generation)
CONVPHPH2−ACT
d
C1136
bin
C1131
2
−
CONVPHPH2−OUT
ph
−
−
−
−
Without limitation, residual value considered
Function
Caution!
The conversion result is not limited. The result must not exceed the range of ±2147483647.
l
C1131 = HIGH
– The phase signal at CONVPHPH2−IN is evaluated with the factor from C1135/1 / C1135/2.
l
C1131 = LOW
– The value 0 is evaluated with the factor from C1135/1 / C1135/2.