Application examples, 3 example 3: path control – Lenze EVS9332xP User Manual
Page 324

Application examples
4.3
Example 3: Path control
4−14
l
EDSVS9332P−EXT DE 2.0
l
Telegram sequence
– Send new position setpoint to slave 1, slave 2 and slave 3
– Send sync telegram
– All slaves reply with CAN−OUT1
Fig. 1
Sequence of communication between master and slaves
Character
Explanation
●
Response of the controller (CAN−IN1)
■
Send setpoint position (from the master) to the controller
1
Slave 1
2
Slave2
3
Slave 3
Input of the target position by an external control (here: PLC)
l
The setpoint position is determined by cyclic set phase increments (t
sync−cycle
) in increments of
milliseconds (
"150μs).
The input must be crystal−precise in the long term.
l
The POS function block calculates the speed and the acceleration.
l
Inputs in v
max
(C1240) and a
max
(C1250) have no effect.
l
This means that speed profiles are possible in any form (e.g. cams).
l
Activation by POSD−PSET−SWT = HIGH (e.g. FIXED1)