Positioning control
3.4.8
Homing
3−52
l
EDSVS9332P−EXT DE 2.0
Move to homing switch, reverse and move to reference point
Mode 4: Traversing direction to the positive end of the travel range limit switch
Set C1213 = 4.
1
?
Home position
Zero pulse / Zero position
Reference switch
(POS-REF-MARK)
9300pos034
Fig. 3−18
Move to POS−REF−MARK, reverse and move to reference point
Function sequence
l
Move towards travel range limit switch with homing speed C1242 up to homing switch
(case
0).
l
Reverse there and move to the reference point. The homing switch must be assigned during
the entire homing process!
l
The reference point is at the first zero pulse / zero position of the position encoder after leaving
the homing switch.
l
If the drive is already positioned on the homing switch before homing it is reversed
immediately (case
1).
Mode 5: Traversing direction to negative end of travel range limit switch
Set C1213 = 5.
Function sequence