22 phase-analog converter (convpha), Phase−analog converter (convpha), Function library – Lenze EVS9332xP User Manual
Page 181: Function blocks, 22 phase−analog converter (convpha), Function, Conversion with adaptation using divisor, Convpha2

Function library
Function blocks
3.5.22
Phase−analog converter (CONVPHA)
3−153
l
EDSVS9332P−EXT DE 2.0
3.5.22
Phase−analog converter (CONVPHA)
Three function blocks (CONVPHA1 ... CONVPHA3) are available.
Purpose
Conversion of a phase signal into an analog value.
CONVPHA1
CONVPHA1
CONVPHA1-OUT
C1002
± 199,99%
CONVPHA1-IN
C1001
2
C1000
1
Fig. 3−105
Function block CONVPHA1
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
CONVPHA1−IN
ph
C1002
dec [inc]
C1001
3
−
CONVPHA1−OUT
a
−
−
−
−
Limited to
±199.99 %
Function
l
Conversion with adaptation using divisor.
l
The conversion is performed according to the formula:
CONVPHA1–OUT
+ CONVPHA1–IN @
1
2
C1000
@ 100%
16384
CONVPHA2
CONVPHA2
CONVPHA2-OUT
C1612
± 199,99%
CONVPHA2-IN
C1611
2
C1610
1
Fig. 3−106
Function block CONVPHA2
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
CONVPHA2−IN
ph
C1612
dec [inc]
C1611
3
−
CONVPHA2−OUT
a
−
−
−
−
Limited to
±199.99 %
Function
l
Conversion with adaptation using divisor.
l
The conversion is performed according to the formula:
CONVPHA2–OUT
+ CONVPHA2–IN @
1
2
C1610
@ 100%
16384