Function library, Function blocks – Lenze EVS9332xP User Manual
Page 310

Function library
Function blocks
3.5.69
Variable table − speed (VTVEL)
3−282
l
EDSVS9332P−EXT DE 2.0
Function
A total of 34 table positions is available.
l
Enter fixed setpoints under C1302.
– 30 table positions (VTVEL−No1 ... VTVEL−No30) are available.
– Subcodes (C1302/1 ... C1302/30) define the table position number.
l
Enter variable setpoints under VTVEL−INx.
– Four table positions (VTVEL−No31 ... VTVEL−No34) are available.
– Signal input via function blocks.
– The setpoints must be transmitted to the table positions before the program set starts and
has access to it.
l
C1382 indicates the setpoints (in % of vmax) on the table positions.
– Select table position (C1382/1 ... C1382/34) with subcode.
l
C1383 displays the setpoints (in inc) on the table positions.
– Select table position (C1383/1 ... C1383/34) with subcode.
l
The conversion from v [units/s] to v [inc] is performed according to the formula:
v [inc]
+ v [unitsńs] @
65536 [inc
ńr] @ gear nominator @ 16384
Feed const. [units
ńr] @ gear denominator @ 1000 [1ńs]
Tip!
Entries into the processing table are only required if FB inputs and outputs are used.