Application examples, 3 example 3: path control – Lenze EVS9332xP User Manual
Page 322

Application examples
4.3
Example 3: Path control
4−12
l
EDSVS9332P−EXT DE 2.0
Adaptation to the example by extending the basic configuration
Please establish the following connections:
POS−MANU−NEG
´
CAN−IN2.B9
POS−MANU−POS
´
CAN−IN2.B10B1
OR1−IN1
´
FIXED0
OR1−IN2
´
FIXED0
POS−LIM−NEG
´
DIGIN1
POS−LIM−POS
´
DIGIN2
POS−MANUAL
´
CAN−IN2.B11
POS−LOOP−INH
´
CAN−IN2.B4
POS−ABS−SET
´
CAN−IN2.B4
POS−PSET−SWT
´
NOT2−OUT
NOT2−IN
´
CAN−IN2.B11
Function of the ’Path control’ after changing the configuration
Input
Level
Function
CAN−IN2.B4
HIGH
Switch off position control circuit
Accept position setpoint as actual position
CAN−IN2.B9
HIGH
Manual operation in negative traversing
direction
CAN−IN2.B10
HIGH
Manual operation in positive traversing
direction
CAN−IN2.B11
HIGH
Activate manual operation