Absolute positioning, Function library, Positioning control – Lenze EVS9332xP User Manual
Page 60

Function library
Positioning control
3.4.3
Positioning modes (C1210)
3−32
l
EDSVS9332P−EXT DE 2.0
3.4.3.2
Absolute positioning
9300POS025
S1
S2
S3
Home position
Limit position
negative
C1224
C1223
End of travel switch
positive direction
POS-LIM-NEG
POS-LIM-POS
POS-REF-MARK
End of travel switch
negative direction
Limit position
positive
Fig. 3−10
Example of a machine with finite traversing range
Purpose
l
Use in applications with finite traversing range, e. g. in warehousing or handling machines.
Function
l
Set positioning mode (C1210) = 0 (default setting)
l
Before starting a positioning drive homing must be carried out (output POS−REF−OK = 1,
homing status C1284 = REF−OK"). By homing the reference point of the measuring system to
the machine is determined (
l
In the absolute positioning mode absolute and relative target positions can be approached.
There are two measuring systems (
– the machine measuring system and
– the real measuring system
l
The travel range limit switches are located in front of the mechanical stops. They prevent the
drive from touching the stops.
l
Adjustable position limiting values (C1223, C1224) prevent the travel range limit switches from
being approached under normal operating conditions. A target position located outside the
position limiting value is not approached. In this case a fault is indicated (P04, P05).