Page 203: Stop

Function library
Function blocks
3.5.29
Digital frequency ramp function generator (DFRFG)
3−175
l
EDSVS9332P−EXT DE 2.0
3.5.29.6
Start via touch probe initiator (terminal X5/E5)
Stop!
In the default setting the terminal X5/E5 is assigned to another function.
Function
l
Set C0757 = 1.
l
The function is activated by simultaneously setting the inputs:
– DFRFG−QSP and DFRFG−RESET = HIGH.
l
Starting procedure:
– Signals at DFRFG−QSP and DFRFG−RESET = LOW.
– Otherwise touch probe signals are ignored.
l
A LOW−HIGH edge at terminal X5/E5 starts the process:
t
DFRFG-RESET
DFRFG-QSP
Touch-Probe X5/E5
DFRFG-OUT
DFRFG-IN
Fig. 3−128
Start via touch probe initiator (terminal X5/E5)