3.5.12
BCD decade switch (BCD)
3−125
l
EDSVS9332P−EXT DE 2.0
3.5.12.7
BCD mode
The BCD mode defines the type of BCD transmission (not the transmission to the target code).
Overview of the settings in the BCD mode:
Function
BCD1
BCD2
BCD3
BCD mode
·
0 = no handshaking
·
1 = handshaking
C1706
C1716
C1726
BCD delay in ms (only for data transmission
without handshaking)
C1707
C1717
C1727
No handshaking, minimum wiring
Set BCD mode = 0.
Function
l
Cyclic reading of BCDs
– No acceptance signal (BCDx−READ), e.g. for reading a BCD decade switch required.
l
Set BCD delay (see table)
– Defines the period between reading the individual BCDs. The setting may be necessary if a
bus system provides the data transfer between the BCD decade switch and the FB BCDx
(e.g. terminal extension via system bus).
– The bus system used, the baud rate, and the bus load determine the time to be set.
The BCDs are read in the following sequence:
1. Sign
2. BCD 1
3. BCD 2
4. etc.