Cancel" function, Reset" function, Function library – Lenze EVS9332xP User Manual
Page 150: Function blocks

Function library
Function blocks
3.5.12
BCD decade switch (BCD)
3−122
l
EDSVS9332P−EXT DE 2.0
3.5.12.3
"CANCEL" function
The identification for "CANCEL" at the inputs BCDx−DATAx results in the following state:
Input/output
Signal
Function
BCDx−EOT
HIGH
Switches
BCDx−NEW−DATA
HIGH
Switches
−
−
Sets BCDs which are not yet read to zero and stops reading.
−
−
The inputs BCDx−DATAx expect the sign as the next BCD.
3.5.12.4
"RESET" function
The identification for "RESET" at the inputs BCDx−DATAx results in the following state:
Function
Input/output
Signal
Switches
BCDx−EOT
LOW
Switches
BCDx−DATA−FLT
LOW
Switches for a millisecond
BCDx−NEW−DATA
LOW
Switches if BCDx−FAIL−IN = LOW is switched at the same time (internal OR link).
BCDx−FAIL
LOW
Switches if BCDx−BUSY−IN = LOW is switched at the same time (internal OR link).
BCDx−BUSY
LOW
The inputs BCDx−DATAx expect the sign as the next BCD.
−
−
The BCD read last remains and can be transmitted to the target code.
−
−