Process data transfer
Cyclic process data objects
Process data signals of Lenze controllers
l
52
EDSMF2178IB EN 3.0
9.3.1
Process data signals of Lenze controllers
9.3.1.1
Process data signals for 8200 vector frequency inverters
A change of code C0001 to 3 preconfigures the process data words in the controller.
)
Note!
Frequency and speed values are normalised with
"24000 5 "480 Hz.
Process data telegram to drive
User data (up to 8 bytes)
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Control
word
Low byte
Control
word
High byte
AIF−IN.W1
Low byte
AIF−IN.W1
High byte
AIF−IN.W2
Low byte
AIF−IN.W2
High byte
xx
xx
Byte description:
Byte
Content
Description
1
C0135
Control word, low byte
Bits 0 ... 7 of the control word under C0135 (
2
C0135
Control word, high byte
Bits 8 ... 15 of the control word under C0135 (
here.
3
AIF−IN.W1, low byte
AIF−IN.Wx is parameterised under code C0412.
4
AIF−IN.W1, high byte
5
AIF−IN.W2, low byte
6
AIF−IN.W2, high byte
7 / 8
xx
No evaluation of these data, any content possible
Process data telegram from drive
User data (up to 8 bytes)
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Status word
Low byte
Status word
High byte
AIF−OUT.W1
Low byte
AIF−OUT.W1
High byte
AIF−OUT.W2
Low byte
AIF−OUT.W2
High byte
xx
xx
Byte description:
Byte
Content
Explanation
1
C0150
Status word, low byte
Bits 0 ... 7 of the status word are entered here under C0150 (
^ 145).
2
C0150
Status word, high byte
Bits 8 ... 15 of the status word are entered here under C0150 (
^ 145).
3
AIF−OUT−W1
Low byte
AIF−OUT.Wx is parameterised under code C0421.
4
AIF−OUT.W1
High byte
5
AIF−OUT−W2
Low byte
6
AIF−OUT.W2
High byte
7 / 8
xx
No evaluation of these data, any content possible