13 i-1015: emergency inhibit time, 14 i-1016: consumer heartbeat time, 13 i−1015: emergency inhibit time – Lenze EMF2178IB User Manual
Page 105: 14 i−1016: consumer heartbeat time, Implemented canopen objects

Implemented CANopen objects
Overview
I−1015: Emergency inhibit time
l
105
EDSMF2178IB EN 3.0
13.2.13
I−1015: Emergency inhibit time
Index (hex)
0x1015
Name
Emergency inhibit time
Subindex
Default
setting
Value range
Access
Data type
0
0
0
...
65535 rw
U16
This object determines the time between two emergency telegrams.
The value entered is multiplied by 0.1, the result is the delay time in milliseconds.
13.2.14
I−1016: Consumer heartbeat time
Index (hex)
0x1016
Name
Consumer heartbeat time
Subindex
Default
setting
Value range
Access
Data type
0
Consumer heartbeat time 0
0
...
65535 ro
U32
1
rw
U32
Subindices
Subindex
Explanation
0
Highest subindex
1
Node ID and "heartbeat time" of node
Bit assignment, subindex 1
U32
31 ... 24
23 ... 16
15 ... 0
Reserved, value 0
Node ID
Heartbeat time [ms]
The "consumer heartbeat time" is used to monitor a node.
The "consumer heartbeat time" must be longer than the "producer heartbeat time" of the
node to be monitored.
If the selected time is exceeded, the communication module will send an emergency
telegram including the "heartbeat error" 0x8130.
Under code C1882/subcode 5, you can set the response of the basic device.