9 i-100d: life time factor, 10 i-1010: store parameters, I−100d: life time factor – Lenze EMF2178IB User Manual
Page 101: 10 i−1010: store parameters, Implemented canopen objects

Implemented CANopen objects
Overview
I−100D: Life time factor
l
101
EDSMF2178IB EN 3.0
13.2.9
I−100D: Life time factor
Index (hex)
0x100D
Name
Life time factor
Subindex
Default
setting
Value range
Access
Data type
0
0
0
...
255 rw
U8
With the default setting of "0", "node guarding" is not supported.
The product of "guard time" and "life time factor" is important for the monitoring process.
13.2.10
I−1010: Store parameters
Parameter storage in the EEPROM
Index (hex)
0x1010
Name
Store parameters
Subindex
Default
setting
Value range
Access
Data type
0
Store parameters
−
0
...
2
32
− 1 ro
U8
1
U32
...
3
Subindices
Subindex
Authorisati
on
Description
Write
Read
0
ro
While writing, the 0x06010002 error
message occurs.
Supported subindex: 3
1
While writing, the 0x08000020 error
message occurs.
Reading of memory functions of all
parameters
2
Reading of memory functions of object
communication parameters
3
Reading of memory functions of
manufacturer−specific parameters
(Index 0x6000 ... 0x9FFF)
Bit assignment (reading)
U32
31
...
2
1
0
0
...
0
0/1
0/1
The following functions are controller−dependent. They are indicated by reading the bit
states 0 and 1.
Bits
Value
Meaning of the bit assignment
0
0
No automatic saving of parameters
1
Automatic saving of parameters
1
0
No saving of parameters on command
1
Saving of parameters on command
2 ... 31
0