beautypg.com

13 parameter reference, C01120 | sync signal source, C01501 | reaction on communication error with mci – Lenze E84AYCET EtherCAT MCI module User Manual

Page 96: Parameter reference, C01120, C01501

background image

13

Parameter reference

13.1

Communication-relevant parameters of the standard device

96

Lenze · E84AYCET communication module (EtherCAT) · Communication Manual · DMS 5.0 EN · 05/2013 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

13

Parameter reference

This chapter supplements the parameter list and the table of attributes in the software manual and

in the »Engineer« online help for the Inverter Drive 8400 by the parameters of the E84AYCET

communication module (EtherCAT).

13.1

Communication-relevant parameters of the standard device

This chapter lists the communication-relevant parameters of the Inverter Drive 8400 in numerically

ascending order.

C01120

C01501

Software manual/online help for the Inverter Drive 8400
Here you will find general information about parameters.

Parameter | Name:

C01120 | Sync signal source

Data type: UNSIGNED_8

Index: 23455

d

= 5B9F

h

Selection of the source for DC synchronisation signals.

• Select "4: MCI" for the communication module.

• In general, only one source can synchronise the drive.

Synchronisation with "Distributed Clocks" (DC) ( 37)

Selection list

(Lenze setting printed in bold)

Info

0 Off

Synchronisation off

1 CAN on board

Synchronisation via the system bus "CAN on board"

4 MCI

Synchronisation via MCI (communication module)

;

Read access ; Write access … CINH … PLC-STOP … No transfer … COM … MOT

Scaling factor: 1

Parameter | Name:

C01501 | Reaction on communication error with MCI

Data type: UNSIGNED_8

Index: 23074

d

= 5A22

h

Configuration of monitoring functions for the communication module
Selection list

0 No response
1 Error
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information

Subcodes

Lenze setting

Info

C01501/1

0: No response

Reaction on MCI communication failure

• Response to a communication error (module in slot)

C01501/2

0: No response

Reaction on MCI module invalid

• Response to an incompatible communication module

or module not in slot

;

Read access ; Write access … CINH … PLC-STOP … No transfer … COM … MOT

Scaling factor: 1