beautypg.com

5 external voltage supply, External voltage supply, External voltage supply ( 31) – Lenze E84AYCET EtherCAT MCI module User Manual

Page 31: 5installation

background image

Lenze · E84AYCET communication module (EtherCAT) · Communication Manual · DMS 5.0 EN · 05/2013 · TD17

31

5

Installation

5.2

Electrical installation

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.2.5

External voltage supply

The communication module can be supplied externally with voltage via separate supply cables at

the 2-pole plug connector X245.

External voltage supply of the communication module is necessary if the bus communication is to

be continued in the event of a failure of the supply of the standard device.
Access to parameters of a standard device disconnected from the mains is not possible.

Wiring plug connector X245

[5-9]

Wiring of the 2-pole plug connector with spring connection

How to wire the plug connector with spring connection:

1. Place a screwdriver in the notch beneath the contact slot and keep it pressed.
2. Insert the supply cable in the contact slot.
3. Remove the screwdriver from the notch.

Note!

With external voltage supply, always use a separate power supply unit, safely separated

to EN 61800-5-1 in every control cabinet (SELV/PELV).

Stop!

Only wire the plug connector if the standard device is disconnected from the mains.

E84AYCXX010