C13881
C13883
C13884
C13885
Parameter | Name:
C13881 | Response time when exiting "Operational"
Data type: UNSIGNED_16
Index: 10694
d
= 29C6
h
If the "Operational" state is exited, the response parameterised with
occurs after the time set here has
elapsed.
A change in monitoring is effective immediately.
Setting range
(min. value | unit | max. value)
Lenze setting
0
ms
65535 0 ms
;
Read access ; Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13883 | DC active
Data type: UNSIGNED_8
Index: 10692
d
= 29C4
h
The code displays if the DC synchronisation has been activated for the communication module.
Synchronisation with "Distributed Clocks" (DC) ( 37)
Selection list
(read only)
Info
0 DC unused
1 DC for synchronisation
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13884 | Base device synchronisation status
Data type: UNSIGNED_8
Index: 10691
d
= 29C3
h
The code displays whether the inverter is DC-synchronised.
Synchronisation with "Distributed Clocks" (DC) ( 37)
Selection list
(read only)
Info
0 Not synchronised
1 Synchronised
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13885 | Clear process data
Data type: UNSIGNED_8
Index: 10690
d
= 29C2
h
This code serves to set which process data the slave is to process for maintaining internal communication when the
EtherCAT has exited the "Operational" state.
Selection list
(Lenze setting printed in bold)
Info
0 Use of most recent master PDOs
The data last sent by the master are used.
1 PDOs are set to the value '0'
The process data contents is set to the value '0'.
;
Read access ; Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT