beautypg.com

3 emergency requests / emergency messages, 1 structure of the emergency message, 11 diagnostics – Lenze E84AYCET EtherCAT MCI module User Manual

Page 90

background image

11

Diagnostics

11.3

Emergency requests / Emergency messages

90

Lenze · E84AYCET communication module (EtherCAT) · Communication Manual · DMS 5.0 EN · 05/2013 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.3

Emergency requests / Emergency messages

Emergency messages are sent to the EtherCAT master once when the error status of the inverter

changes, i.e. ...

• when an error in the inverter or in the communication module occurs;
• when an internal error of the communication module is eliminated.

An "Emergency Request" on the fieldbus consists of the components "Mailbox Header", "CANopen

Header" and the actual "Emergency Message":

The emergency message last sent by the Inverter Drive 8400 is displayed in code

C13867

.

Code

C13887

serves to select the error responses where no emergency messages are to be sent to

the EtherCAT master.

11.3.1

Structure of the Emergency message

Example: Emergency message of the error "

Operational status quit [0x01bc8131]

"

• Bytes 1 and 2 display that an error is pending.
• Byte 3 display the contents of the error register (I-1001).
• Bytes 5 ... 8 contain the error code.

Mailbox header

CANopen

header

Emergency Message

6 bytes

2 bytes

8 bytes

Byte 1

Byte2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Emergency

Error code

Error

Register

(I-1001)

Reserved

Error code

Inverter Drive 8400 / E84AYCET

Low byte

High byte

Low byte

High byte

Low word

High word

Low byte

High byte

Low byte

High byte

0x00

0x10

0x01

0x00

0x31

0x81

0xbc

0x01

Software manual/online help for the Inverter Drive 8400
Here you will find detailed information on the error codes.