4technical data – Lenze E84AYCET EtherCAT MCI module User Manual
Page 17
Lenze · E84AYCET communication module (EtherCAT) · Communication Manual · DMS 5.0 EN · 05/2013 · TD17
17
4
Technical data
4.2
Protective insulation
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
The following illustration ...
• shows the arrangement of the terminal strips and the separate potential areas of the inverter.
• serves to determine the decisive protective insulation between two terminals located in
differently insulated separate potential areas.
[4-1]
Protective insulation in accordance with EN61800-5-1
E84YCXX007
Reinforced insulation
Basic insulation
Functional insulation
X4
X6
X5
X3
Bus
Ext. DC
MCI
X4
X6
X5
X3
X1
X1
X105
X105
X100
X100
MMI
X106
X106
X106
X106
X106
X106
X106
X101
Terminal strip Connection
X100 Mains / DC bus connection
X101 Relay contact
X105 Motor/brake resistor
X106 Motor PTC
X1 System bus (CAN)
X3 Analog inputs/outputs
X4 Digital outputs
X5 Digital inputs
X6 Diagnostics
MCI Slot for communication module