beautypg.com

2 fieldbus status displays, Fieldbus status displays ( 86), Fieldbus status displays – Lenze E84AYCET EtherCAT MCI module User Manual

Page 86: Tivated (see, Should be lit, 11 diagnostics

background image

11

Diagnostics

11.1

LED status displays

86

Lenze · E84AYCET communication module (EtherCAT) · Communication Manual · DMS 5.0 EN · 05/2013 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.1.2

Fieldbus status displays

The LEDs BS and BE show the fieldbus status.

[11-2] LEDs BS, BE

E84YCET006

BS

BE

LED

Colour

State

Description

BS

green

off

The communication module is not active on the fieldbus or is in the

"Init" state.

blinking

"Pre-operational" status is active:

• Access to parameters and objects is possible.

• No process data exchange.

blinking once

(single flash)

"Safe-operational" status is active:

• The data are not yet active in the standard device.

on

The communication module is in the "Operational" state.

200 ms

200 ms

1000 ms

200 ms

200 ms

1000 ms