beautypg.com

11 diagnostics – Lenze E84AYCET EtherCAT MCI module User Manual

Page 87

background image

Lenze · E84AYCET communication module (EtherCAT) · Communication Manual · DMS 5.0 EN · 05/2013 · TD17

87

11

Diagnostics

11.1

LED status displays

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

BE

red

off

No fault

blinking

The configuration is invalid/faulty.

blinking once

(single flash)

• A non requested state change has occurred. (The slave

application has autonomously changed the EtherCAT status.)

• Synchronisation error (The EtherCAT node automatically changes

to the "Safe-operational" state.)

blinking twice

(double flash)

An "Application Watchdog Timeout" or a "Sync Manager Watchdog

Timeout" has occurred.

LED

Colour

State

Description

200 ms

200 ms

1000 ms

200 ms

200 ms

1000 ms

200 ms

200 ms

1000 ms

200 ms

200 ms

200 ms