Granular chemical attachment, Spring tooth incorporator, Fertilizer check valve cleaning and repair – Kinze 3200 Wing-Fold Planter Rev. 7/14 User Manual
Page 163: Granular chemical attachment -23, Spring tooth incorporator -23, Fertilizer check valve cleaning and repair -23
TM
Model 3200
M0241-01
6/11
7-23
Lubrication and Maintenance
Before storing planter, disengage granular chemical drive by
rotating throwout knob ¼ turn counterclockwise. Remove drive
chain and empty and clean all granular chemical hoppers.
Clean drive chains and coat them with a rust preventive spray
or submerge chains in oil. Inspect and replace worn or broken
parts.
Install hoppers and chains. Check chain alignment.
Before storing planter, inspect each spring tooth incorporator
and replace worn or broken parts. Check for loose hardware
and tighten as needed.
Disengage
Engage
GRANULAR CHEMICAL ATTACHMENT
SPRING TOOTH INCORPORATOR
Granular chemical throwout knob
Spring tooth incorporator
FERTILIzER CHECK VALVE CLEANING AND REPAIR
1. Unscrew valve body and separate halves. Note direction and location of parts.
2. Clean and inspect parts. Flush with clean water. Replace damaged parts.
3. Reassemble exactly as shown. O-ring and valve seat must be firmly in place inside each half of valve body.
Direction of flow
Valve seat
Valve ball
Guide
O-ring
Spring