Field operation -46, Kpm iii monitor operation, Rev. 7/12 – Kinze 3200 Wing-Fold Planter Rev. 7/14 User Manual
Page 136: Setup mode
M0241-01
Model 3200
6-46
Rev. 7/12
TM
KPM III Monitor Operation
NOTE: Planter monitor configuration above has an even
number of front (Interplant) rows (8).
STEP 7
Sensor Present Warning – One or more sensors are
present on Muxbus.
Status
Plant
About
Setup Mode
Configuration:
Effective row spacing: 15.0
Front / Rear
1. General Settings
2. Seed Meter Settings
3. Row Unit Alarm Levels
4. Setup Data Logging
5. Configure Planter Monitor
6. Add New Muxbus Sensors
7. Add Single Interplant Row
8. Select Speed Sensor
9. Sensor Setup
10.Calibrate Speed Sensor
Logdata
The planter monitor configuration must
contain an odd number of front rows
before the single leftmost interplant row
unit can be added.
Add Interplant Row Error
OK
Status
Plant
About
Setup Mode
Configuration:
Effective row spacing: 15.0
Front / Rear
1. General Settings
2. Seed Meter Settings
3. Row Unit Alarm Levels
4. Setup Data Logging
5. Configure Planter Monitor
6. Add New Muxbus Sensors
7. Add Single Interplant Row
8. Select Speed Sensor
9. Sensor Setup
10.Calibrate Speed Sensor
Logdata
One or more sensors are present on the
Muxbus.
The monitor can not be reconfigured
until all sensors are disconnected from
the Muxbus.
Sensors Present Warning
OK
F1
F2
F4
F3
MPH
Avg
Pop
0
0.0
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
120
110
100
90
80
70
60
%
120
110
100
90
80
70
60
%
Contrast
Alarm
Rear Row 1
wake failed
20 more of same type
F1
Ignore this sensor
F2
Keep trying this sensor
F3
Ignore All failed wakes
F4
Keep trying All
Status
Normal
Average
Section
Freeze
0.00
1 2 3 4 5 6 7
1 2 3 4 5 6 7 8
120
110
100
90
80
70
60
%
120
110
100
90
80
70
60
%
ACF
R2
Pop
Scan
0
STEP 8
Alarm: Rear Row 1 wake failed – Select an option
from warning box and press key next to selection.
FIELD OPERATION
Press ON/OFF key to turn monitor ON.
If monitor has been configured, it will show Planter Configuration
screen and attempt to communicate with seed sensors.
NOTE: Do not attempt planting before ‘‘Wait For Calibration’’
message disappears. If planter is moving while sensors are
calibrating alarms will be generated.
NOTE: If monitor can communicate with sensors Planter
Configuration screen displays.
If monitor does not detect sensors message below displays.
NOTE: Selecting OK reconfigures monitor requiring all
sensors to be re-learned. Selecting Cancel keeps current
configuration and monitor continues trying to communicate
with sensors.
RowPop
Spacing
Area
Other
Accuracy
Avg
Pop
0
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
120
110
100
90
80
70
60
%
120
110
100
90
80
70
60
%
0.66
AC3
Sensors Calibrating
Wait for Calibration...
RowPop
Spacing
Area
Other
Accuracy
Avg
Pop
0
0.00
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
120
110
100
90
80
70
60
%
120
110
100
90
80
70
60
%
ACT
RowPop
Spacing
Area
Other
Accuracy
Avg
Pop
0
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
120
110
100
90
80
70
60
%
120
110
100
90
80
70
60
%
0.0
AC3
No Sensors Detected
Reconfigure the planter monitor?
No sensors were detected, but
the planter monitor is configured.
Select OK to reconfigure the monitor.
Select Cancel to retain the current
planter monitor configuration.
Cancel
OK
STEP
6
Add Interplant Row Error – Planter monitor
configuration must contain an odd number of front
rows before single Interplant row unit can be added.