Area counter/speedometer mode -13, Programming - clearing total area -13, 13 kpm ii monitor operation – Kinze 3200 Wing-Fold Planter Rev. 7/14 User Manual
Page 103

TM
Model 3200
M0241-01
6/11
6-13
KPM II Monitor Operation
NOTE: If a discrepancy occurs and digits must be changed, follow STEPS 1 and 2 to enter the programming mode and proceed as follows:
•Press the OK key and the flashing arrow becomes solid. The least significant digit of the displayed value will be blinking.
•This value can be changed by pressing UP or DOWN arrow keys.
•Once digit is correct, press the SELECT key and the blinking digit moves to the next significant digit, where the process can be repeated.
Pulses per mile or kilometer are limited to a range from 500 PPM (310 PPKM) to 500,000 PPM (310,686 PPKM).
KEy Action
Flashing Digit
Display Value
Press The UP Key
Right Most Digit
203
1, 2032, 2033
Press The SELECT Key
Second Digit From Right
20
33
Press The DOWN Key
Second Digit From Right
20
23, 2013, 2003,
20
93, 2083
Press The SELECT Key Twice
Left Most Digit
2083
Press The DOWN Key
Left Most Digit
1083, 0500 (Min.
Value),
9500, 8500
PROGRAMMING - CLEARING TOTAL AREA
NOTE: Clearing the total area counter will also clear the field
area counter.
STEP 1 To enter the programming mode, press and hold
the SETUP key. The monitor will emit several short
beeps followed by a long beep. On the lower LCD,
the SETUP icon turns on and the arrow head icon
will flash, indicating that the user can select an item
to program.
NOTE: Monitor must be in a programmable function (row
spacing, units, speed, volume or area) to enter setup. The
monitor will not enter setup in seed population or seed
spacing.
STEP 2 Press tUP or DOWN arrow keys to move flashing
arrow to TOTAL AREA. As the arrow icon moves, the
lower LCD will display the current setting of the item
selected.
STEP 3 Press the OK key and flashing arrow becomes solid
and audible alarm sounds.
•The lower LCD will display the total area and the
ACRE (or Ha) icon turns on.
•With the flashing arrow on TOTAL AREA, press the
OK key.
•To reset counter, press the UP and DOWN arrow
keys at the same time and hold them down for a short
period of time to clear the data. The CLEAR? icon will
be displayed and the monitor will beep several times.
When the data is actually cleared, the monitor will
emit a long beep, and the total area is reset to zeros.
After the long beep, the previous recorded total area
is not retrievable. Once cleared, the user
may not
choose to exit programming mode without saving as
described in STEP 4.
STEP 4 To exit and save, press and hold the OK key. The
monitor emits several short beeps and SAVE? icon is
turned on. After a short time a long beep is heard, and
the lower LCD will display the word “DONE”. Release
the OK key. If the OK key is released BEFORE the
word “DONE” is displayed, the changes WILL NOT
BE SAVED. The word “DONE” MUST be displayed in
order for the save to have occurred.
NOTE: Programming mode may be exited at any tim by
pressing the SETUP key. Pressing this key returns the
monitor to its normal operation. All items changed and
saved come into effect immediately. Any items changed, but
not saved revert to original programmed value.
AREA COUNTER/SPEEDOMETER MODE
If the monitor is installed with only a radar distance sensor (no
seed tubes attached), the monitor becomes a speedometer. If (a)
the monitor is connected to a radar distance sensor, (b) signal
cable from back of console is connected to a sensing switch
(Part No. G1K249 Acre Counter Switch Kit) instead of seed tubes
and (c) implement width in feet (or meters) is programmed into
monitor, monitor functions as an area counter.
Seed spacing and seed population functions are not available
in this mode. If the monitor is powered down, the seed tubes
connected and the monitor powered up, the monitor again shows
seed population and seed spacing in inches or centimeters. Row
spacing reverts back to its programmed setting.