KPM II Monitor Operation
FIELD AREA/TOTAL AREA
Each AREA FIELD/TOTAL key press alternates between field area and total area.
Field area displays total number of acres or hectares using a 6 digit, one decimal place format.
NOTE: When FIELD AREA is selected, the UP or DOWN key must be held in slightly longer than normal so monitor will not mistake
this action with a CLEAR, which consists of the UP and DOWN arrow keys pressed simultaneously. A beep will sound when the
function activates.
Total area displays total number of acres or hectares using a 6 digit, one decimal place format. The total area counter updates every time
the field area counter increments. Clearing total area counter will also clear field area counter.
When the monitor is programmed as a rear only or rear/front configuration and shaft rotation sensors are installed, pressing UP arrow to
move beyond row spacing lights an arrow on an unlabeled area above ROW SPACING. This is the automatically set division line between
L.H. shaft sensor and R.H. shaft sensor. The display shows first row on rear section and front section assigned to R.H. shaft rotation sensor.
ExAMPLE: On a 12 Row 30" planter with Interplant Package, the display appears as follows:
THIS DISPLAY IS NOT ACCESSIBLE ON LEFT/RIGHT CONFIGURATIONS OR SYSTEMS WITHOUT SHAFT ROTATION SENSORS.
PROGRAMMING - CHANGING AUDIbLE ALARM
VOLUME
STEP 1 To enter programming mode, press and hold the
SETUP key. The monitor emit s several short beeps,
followed by a long beep. On the lower LCD, the
SETUP icon turns on and the arrow head icon will
flash, indicating that the user can select an item to
program.
NOTE: Monitor must be in a programmable function (row
spacing, units, speed, volume or area) to enter setup. The
monitor will not enter setup in seed population or seed
spacing.
STEP 2 Press UP or DOWN arrow keys to move the flashing
arrow to VOLUME. As the arrow icon moves, the
lower LCD displays the current setting of the selected
item.
STEP 3 Press the OK key and the flashing arrow becomes
solid and the audible alarm will sound.
NOTE: The lower LCD displays the current volume and the
SPEAKER icon is turned on. Settings are from 0 to 9.
•Use UP or DOWN arrow keys to change the setting.
With every UP arrow key push, the alarm will
increment by one step between the minimum and the
maximum. If the maximum level (9) is reached the
volume rolls over to the minimum level (0).
•Pressing the DOWN arrow key lowers the volume
until the minimum level (0) is reached, at which point
the volume rolls over to the maximum level (9).
STEP 4
To exit without saving, press and release the OK key.
The monitor restores the lower LCD to show the item
setting and the arrow icon flashes, allowing the user
to select another item to program.
To exit and save, press and hold the OK key. The
monitor emits several short beeps and SAVE? icon
is turned on. After a short time a long beep is heard,
and the lower LCD displays “DONE”. Release the OK
key. If the OK key is released BEFORE “DONE” is
displayed, changes WILL NOT BE SAVED. “DONE”
MUST be displayed in order for the save to have
occurred.
NOTE: Programming mode may be exited at any time,
by pressing the SETUP key. Pressing this key returns the
monitor to its normal operation. All items changed and
saved will come into effect immediately. Any items changed,
but not saved will revert to the original programmed value.