4 configuration parameters – JUMO 706560 LOGOSCREEN es Operating Manual User Manual
Page 89

89
4 Configuration parameters
Default text
(Ext.report/
Batches)
Configuration
➔ Report/Batches
➔ Ext. report/Batches
➔ Batches
➔ Line 1 — 10
➔ Default text
any text
Only used for “right-hand
column = fixed text”.
v Chapter 3.2.8 “Batch
Text editable?
(Ext.report/
Batches)
Configuration
➔ Report/Batches
➔ Ext. report/Batches
➔ Batches
➔ Line 1 — 10
➔ Text
editable?
Yes,
No
“Yes” means that the
preset text can still be
altered, as long as the
batch has not been
completed.
v Chapter 3.2.8 “Batch
Daily report
Configuration
➔ Report/Batches
➔ Daily report
Off,
On
If a report is Off, it cannot
be called up. It will be
skipped automatically
when switching reports.
Monthly report
Configuration
➔ Report/Batches
➔ Monthly report
Off,
On
Annual report
Configuration
➔ Report/Batches
➔ Annual report
Off,
On
Period
(report)
Configuration
➔ Report/Batches
➔ Period
1, 2, 3, 4, 5, 10, 15, 30min,
1 ,2 ,3 ,4 ,6 ,8 ,12h
Only for period. report
Synchronization
time
(report)
Configuration
➔ Report/Batches
➔ Synchronizat. time
any time
00:00:00
All reports except external
report.
Example:
Setting:
Synchronizat. time = 03.00
period = 6hrs
current time = 02:15
effect:
1st period report =
02:15 - 03:00
2nd period report =
03:00 - 09:00
3rd period report =
09:00 - 15:00
4th …,
daily report = 03:00
of each day,
monthly report = 03:00
on first day of each month,
annual report = 03:00
on the 1st Jan. of each
year