6.1.2 CM Program
• After "Display" is selected, a window opens in which all of the functions used in
the currently opened CM program will be listed, together with inscriptions and
parameters.
The list can be printed out by selecting "Print".
Pressing "Close“ takes you back to the CM Editor.
• With "Simulate", you can simulate and/or test the CM program that is currently
open. The Simulation window opens for this purpose. No connection with the
CMU 1000 is required for the simulation.
All of the input signals used in the CM program are listed one above the other
in the Name column in the left-hand part of the Simulation window.
You can assign a specific value to each input in the Input value column.
All of the actions used in the CM program are listed one above the other in the
Name
column in the right-hand part of the Simulation window.
The current status of each action is displayed in the Value column.
The cycle number of the last status modification is displayed in the Cycle
column.
The date and time of the last status modification is displayed in the Time
column.